LUTRON DW-6095 3 PHASE POWER ANALYZER WITH HARMONIC
LUTRON DW-6095 3 PHASE POWER ANALYZER WITH HARMONIC
The Lutron DW-6093 SD electrical analyzer from Taiwan is designed to measure electrical parameters such as voltage, current, power, and frequency. It supports measurements of 1p:2w, 1p:3w, 3p:3w, and 3p:4w and can store data via an SD card, with the data downloadable as an Excel file without the need for additional software. Functions include ACV, ACA, power factor, phase angle, frequency, active (real) power, apparent power, reactive power, watt-hour, VA-hour, VAR-hour, and harmonics.
LUTRON DW-6095 3 PHASE POWER ANALYZER WITH HARMONIC adalah alat analisis kualitas daya dan harmonik 3 fasa profesional yang dirancang untuk audit energi, pemantauan kelistrikan industri, serta pencarian gangguan daya. Alat ini mengintegrasikan fungsi data logger berbasis waktu nyata menggunakan kartu SD standar, sehingga data pengukuran dapat langsung diekspor ke format Excel tanpa memerlukan perangkat lunak tambahan.
FEATURES:
- Analysis for 3 phase multi-power system, 1P/2W, 1P/3W, 3P/3W, 3P/4W.
- 3 current probes (CP-1201) are included, if change the current probes, the calibration procedures are not necessary.
- Current probe input signal/ranges with selection:
- Input signal (ACV): 200mV / 300mV / 500mV / 1V / 2V / 3V.
- Ranges (ACA): 20A / 200A / 2000A / 30A / 300A / 3000A.
- Meter can cooperate the universal current probes.
- Complete set with 4 PCs Test Leads, 4 PCs Alligator clips, 3 PCs Clamp Probe (CP 1201), AC to DC 9V adapter, 2GB SD memory card and Carrying bag.
Measurement: - V (phase-to-phase), V (phase-to-ground)
- A (phase-to-ground)
- KW / KVA / KVAR / PF (phase)
- KW / KVA / KVAR / PF (system)
- KWH / KVAH / KVARH / PFH (system)
- Phase angle
- Harmonics display (1-50th order).
- Simultaneous display of Harmonics and Wave form.
- Display of Waveform with Peak Values.
- Analysis of Total Harmonic Distortion (THD).
- Graphic Phase diagram with 3-Phase system parameters.
- 3 phase Voltage or Current Unbalanced Ratio (VUR, AUR) and Unbalanced Factor.
- Calculated Unbalanced Current through Neutral Line (An).
- Capture Transient events (including Dip, Swell and Outage) with programmable threshold (%).
- Programmable CT ratio (1 to 600) and PT ratio (1 to 1000).
- ACV input impedance is 10 MΩ.
- Safety Standard : IEC 1010, CAT III 600V.
- Built-in clock and Calendar, real time data record with SD memory card, sampling time set from 2 to 7200 seconds. Just slot in the SD card into the computer, it can down load the all the measured value with the time information (year, month, data, hour, minute, second) to the Excel directly, then user can make the further data analysis by themselves.
- Powered by AA (UM-3) DC 1.5 V X 8 batteries (Alkaline type) or DC 9V adapter.
- Computer data
Spesifikasi
- Circuit: Custom one-chip of microprocessor LSI circuit
- Display:
* LCD Size : 81.4 X 61 mm ( 3.2 X 2.4 inch )
* Dot Matrix LCD (320 X 240 pixels ) with back light - Measurement:
V (phase-to-phase)
V (phase-to-ground)
A (phase-to-ground)
KW / KVA / KVAR / PF (phase)
KW / KVA / KVAR / PF (system)
KWH / KVAH / KVARH / PFH (system)
Power factor
Phase angle
Frequency
Harmonics display. - Wire connections: 1P/2W, 1P/3W, 3P/3W, 3P/4W
- Voltage ranges: 10 ACV to 600 ACV, auto range
- probe Current input signal and range:
Current probe input signal volage ( ACV ) : 200mV/300mV/500mV/1V/2V/3V
Current probe input current range ( ACA ) : 20 A/200A/2000A (1200 A)/30A/300A/3000A
Meter can cooperate the universal current probe. - Safety standard: IEC1010 CAT III 600 V.
- ACV input impedance: 10 Mega ohms.
- Range select:
* ACV: Auto range.
* ACA: Manual range - Clamp frequency response: 40 Hz to 1 KHz.
- Spec. tested frequency: 45 to 65 Hz.
- Over load protection:
* ACV: 720 ACV rms
* ACA: 1300 ACA with clamp probe - Data Hold: Freeze the display reading.
- Data Record: SD Card Record.
- Sampling Time: Approx. 1 second.
- Power ON/OFF: Manual OFF by push button
- Over Indicator:
* LCD display show ” OL “.
* The data save into the SD card will show ” 9999 ” or ” 999 ” ( overleap the decimal point ) - Under Indicator:
* LCD display show ” UR “.
* The data save into the SD card will show ” 9999 ” or ” 999 ” ( overleap the decimal point ). - Real time data logger:
* Real time data logger, saved the data into SD memory card and down load the all the measured value with the time information ( year/month/data/hour/minute/second ) down load to the Excel
* Sampling time for data logger : 2 seconds to 7200 seconds, the during of setting step are 2 seconds. - Data Output USB/RS232: RS232 computer serial interface :
* Connect the optional USB cable USB-01 will get the USB plug.
* Connect the optional RS232 cable UPCB-02 will get the RS232 plug. - Operating Temperature: 0 to 50 ℃ ( 32 to 122 ℉).
- Operating Humidity: Less than 80% R.H..
- Power Supply:
* DC 1.5V, AA ( UM-3 ) Battery X 8 PCs (Alkaline or heavy-duty battery).
* AC to DC 9V power adapter. - Power Consumption:
* Meter : 500 DCmA.
* Clamp : 34 DCmA. - Clamp max. conductor Size: 50 mm ( 2.0 inch ) Dia
- Weight:
* Meter : 948g ( includes batteries )
* Clamp ( includded cable ) : 467g - Dimension:
Meter : 225 X 125 X 64 mm ( 8.86 X 4.92 X 2.52 inch )
Clamp : 210 X 64 X 33mm ( 8.3 X 2.5 X 1.3 inch )
Clamp Jaw : 86 mm (3.4 inch)- outside
Accessories Included:
- Instruction manual…………… 1 PC
- Test Leads (TL88-4AT)………. 1 Set (4 PCs)
- Alligator clips (TL88-4AC) 1 Set (4 PCs)
- Clamp Probe ( CP-1201 )……. 3 PCs
- AC to DC 9V adapter…………..1 PC
- SD card ( 2 G )……………….. 1 PC
- Carrying bag……………………. 1 PC
Optional Accessories:
- 2000 Amp current probe, CP-2000
- 200 Amp current probe, CP-200
- Flexible 3000 Amp current probe, CP-3000
- USB Cable , USB-01
- RS232 cable, UPCB-02
- Data Acquisition software, SW-U811

Mohon Tanyakan Stok Terlebih Dahulu Sebelum Order.